GarryRF
13 Nov 153#14
You can't hard wire into an existing socket. The sockets in the Kitchen are wired in 2.5mm twin and earth cable and protected by a 32amp circuit breaker in the Electric box. The ALDI extension uses a 1.25mm. cable and should be protected by a 13amp fuse.. You cant change cable sizes without another fuse to protect the smaller cable. Just use the RCD plug in so no one gets hurt.
All comments (20)
udhuk
12 Nov 15#1
Looks like a good deal, heat
bauer
12 Nov 15#2
1.25mm cable?
When wiring this socket I suggest putting a plug on the end of it and plugging it in, don't hard wire it in to a circuit.
compadre to bauer
12 Nov 15#3
That's what the RCD is for, you wire it to the RCD and then plug that in to a socket.
bauer
12 Nov 15#4
Didn't realise it had a plug in RCD with it
compadre
12 Nov 15#5
They tend to be plug in but I would check before purchase, it may be inline but I doubt it.
Looks very similar to homebase BG socket and RCD.
Rickardo
13 Nov 15#6
Just so folks are clear, it's either the extension box or the walk socket for the price, not both!
ro53ben
13 Nov 15#7
You'll likely need a sparky to sign it off if hard wiring it in directly.
andynicol to ro53ben
13 Nov 15#9
Don't think you do, these are simply extension leads , only needs RCD hard wired onto cable once its been fed through window frame etc.
andynicol
13 Nov 15#8
Comes with a hard wired RCD, reason it isn't already fitted, apart from the money saving aspect from the retailer, is so the cable can be fed through window frames etc, then wired.
Jamie Jay
13 Nov 15#10
Got one of these last year, excellent and simple. Drilled hole through garage, plugged into the socket in there and screwed on the wall outside the garage.
MannyFresh
13 Nov 15#11
Wouldn't a in-line outside plug be better? You could hard wire it into the kitchen ring main? Via an existing kitchen socket.
andynicol to MannyFresh
13 Nov 151#15
Do NOT do this, see GarryRF's reply above.
MannyFresh
13 Nov 15#12
So basically spur of an existing kitchen socket
ro53ben
13 Nov 15#13
Like I said, you'll need a sparky if wiring DIRECTLY, i.e. without the RCD plug, like MannyFresh suggests.
GarryRF
13 Nov 153#14
You can't hard wire into an existing socket. The sockets in the Kitchen are wired in 2.5mm twin and earth cable and protected by a 32amp circuit breaker in the Electric box. The ALDI extension uses a 1.25mm. cable and should be protected by a 13amp fuse.. You cant change cable sizes without another fuse to protect the smaller cable. Just use the RCD plug in so no one gets hurt.
andynicol
13 Nov 15#16
My bad, I thought you were referring to hard wiring the supplied RCD.
As comment above, taking a spur off the ring main, or radial, is not an option.
Leftfield_2k2
14 Nov 151#17
Just remember that when you drill external holes that you angle the drill bit so as you drill at a slight angle UP into the house, this along with gravity will prevent water entering your house.
GarryRF
15 Nov 15#18
Or do what the pro's do and buy a tube of invisible/clear waterproof silicone seal. The remainder of the tube will have a hundred uses around the home.
andynicol to GarryRF
15 Nov 15#19
Or do what the real pros do and drill upwards as suggested AND seal with appropriate sealer..?
GarryRF
15 Nov 15#20
If you have cable exposed on the outside wall then you leave a small "U" bend in the cable so the drips fall off before entering the wall. Drill straight into the wall using a mortar joint between bricks. Use a smaller than required masonry drill bit and open up the hole from both sides to the required size. Avoids excess damage to the interior plaster.
Opening post
Weatherproof Outdoor Power Kit
Includes a 4 Socket Extension Lead with 6m Cable
24 hour timer
Safety RCD to guard against shocks
Top comments
All comments (20)
When wiring this socket I suggest putting a plug on the end of it and plugging it in, don't hard wire it in to a circuit.
Looks very similar to homebase BG socket and RCD.
Do NOT do this, see GarryRF's reply above.
As comment above, taking a spur off the ring main, or radial, is not an option.